Model |
2630 |
2660 |
|
Ground Bond Tester |
Ground Bond Tester |
Input |
Voltage |
115/230V selectable +/- 15% |
Frequency |
50 /60 Hz ± 5% |
Fuse |
6.3A 250V Slow Blow |
15A 250V Slow Blow |
|
Ground Bond Test mode |
Output |
- Current |
3.0 - 30.0 Amps AC |
3.0 - 60.0 Amps AC |
- Resolution |
0.1 Amp |
- Regulation |
± (2% of setting + 0.02 A) |
- Voltage |
6 VAC, fixed |
12 VAC, fixed |
Output Frequency |
50 / 60 Hz user selectable |
Dwell Timer |
|
- Range |
0 and 0.5 - 999.9 seconds |
0 for continuous running |
- Resolution |
0.1 second |
- Accuracy |
± (0.1% of setting + 0.05 seconds) |
High Limit |
- Range |
0 - 510 mΩ |
0 - 600 mΩ |
- Current |
0 - 510 mΩ for 0.0 - 10.0 Amps |
0 - 600 mΩ for 0.0 - 15.0 Amps |
0 - 200 mΩ for 10.1 - 25.0 Amps |
0 - 300 mΩ for 15.1 - 30.0 Amps |
0 - 150 mΩ for 25.1 - 30.0 Amps |
0 - 150 mΩ for 30.1 - 60.0 Amps |
- Resolution |
1 mΩ |
- Accuracy |
± (2% of setting + 2 mΩ) |
Offset Capability |
- Range |
0 - 100 mΩ |
- Resolution |
1 mΩ |
- Accuracy |
± (2% of setting + 2 mΩ) |
Current Display |
- Range |
0.0 - 30.0 Amps |
0.0 - 60.0 Amps |
- Resolution |
0.1 Amp |
- Accuracy |
± (3% of reading + 0.03 Amps) |
Ohmmeter Display |
|
- Range |
0 - 510 mΩ |
0 - 600 mΩ |
- Resoultion |
1 mΩ |
- Accuracy |
± (2% of reading + 2 mΩ) |
± (3% of reading + 3 mΩ) for 3 - 5.9 Amps |
|
± (2% of reading + 2 mΩ) for 6 - 60 Amps |
|
Timer Display |
- Range |
0.1 – 999.9 sec |
- Resolution |
0.1 sec |
- Accuracy |
± (0.1% of reading + 0.05 sec) |
|
General Specifications |
Remote Control and Signal Output |
The following input and output signals are provided through two 9-pin D-type connectors:
1. Remote control: Test, Reset, and Withstand Processing
2. Outputs: Pass, Fail, Test-in-Process, Start Out, and Reset Out |
Memory |
5 sets |
Security |
Key Lock capability to avoid unauthorized access to all test parameters. Memory Lock capability to avoid unauthorized access to memory locations. |
Line Cord |
Detachable 6’ (1.80 m) power cable terminated in a three prong grounding plug. |
Terminations |
5’ (1.52 m) high current and return leads with clips |
Mechanical |
Tilt up front feet |
Dimensions (W x H x D) |
11” x 3.5” x 14.56” (280 x 89 x 370 mm) |
16.875” x 5.25” x 15.625” (430 x 130 x 400 mm) |
Weight |
20 lbs. (9 kg |
44.1 lbs. (20 kg) |
Environmental |
|
- Operating Temp |
32˚ - 104˚F (0˚ - 40˚C) |
- Relative Humidity |
-20% to 80% |
Calibration |
Traceable to National Institute of Standards and Technology (NIST). Calibration controlled by software. Adjustments are made through front panel keypad in a restricted access calibration mode. Calibration information stored in non-volatile memory |